Sharps injuries with Lovenox and generic enoxaparin prefilled safety syringers: (Record no. 9260)

MARC details
000 -LEADER
fixed length control field 01658nam a22001937a 4500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20231025132453.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 231025b ph ||||| |||| 00| 0 eng d
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 0360-4039
040 ## - CATALOGING SOURCE
Transcribing agency OCT
100 ## - MAIN ENTRY--PERSONAL NAME
Personal name Grimmond, Terry
240 ## - UNIFORM TITLE
Uniform title Nursing 2023
Medium July 2023
245 ## - TITLE STATEMENT
Title Sharps injuries with Lovenox and generic enoxaparin prefilled safety syringers:
Remainder of title A 12-year retrospective cross-sectional analytical study
Statement of responsibility, etc. Terry Grimmond, MaryAnn Gruden, Bobbi Jo Hurst, and Lydia F. Crutchfield
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Hangerstown, MD
Name of publisher, distributor, etc. Wolters kluwer Health
Date of publication, distribution, etc. 2023
300 ## - PHYSICAL DESCRIPTION
Extent vo. 53 (7) ;pages53-60
505 ## - FORMATTED CONTENTS NOTE
Formatted contents note Abstract:<br/>Purpose: Investigate the incidence and mechanisms of sharps injuries (SI) to staff using Lovenox and generic enoxaparin prefilled syringers.<br/>Methods: Four national adverse event databases were examined over a 12-year period for incidence and brands involved with injury events to staff using enoxaparin prefilled syringers.<br/>Results: The search revealed 581 adverse events (including 20 sharps injuries) associated with device malfunction in 8 of 16 brands, with one brand mentioned significantly more frequently than others. No national alert had been issued. <br/>Conclusion: Use of certain brands of enoxaparin prefilled syringers poses a small but serious risk of injury to staff. Conducting root cause analyses on all SI is essential, as is the need for regularly evaluating safer devices, reporting all device incidents, enabling simpler reporting of adverse events, and establishing more effective intervention by FDA and manufacturers.
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Enoxaparin, lovenox, malfunction
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Grimmond, Terry
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Continuing Resources
Suppress in OPAC No